Technical Data Sheet ASW 8K-LT-G2 ASW 10K-LT-G2 ASW 12K-LT-G2
Input DC
Max PV array Power12000 WP STC15000 WP STC18000 WP STC
Max in put voltage 1100 v 1100 v1100 v
MPP Voltage range/ rated input voltage150 v to 1000 v / 630 v150 v to 1000 v / 630 v150 v to 1000 v / 630 v
Main Input voltage 125 V125 V125 V
Initial Feed- in voltage150 V150 V26 A /26 A
Max Operating input current
26 A /13 A26 A /13 A40 A / 40 A
Max short circuit current40 A / 20 A40 A / 20 A2/A:2; B:1
Number of independent MPP inputs/ String per MPP input2/A:1; B:12/A:1; B:1
OUTPUT AC:
Rated active power8000 W10000 W12000 W
Max apparent AC Power8000VA10000 V A12000 V A
AC nominal voltage 220 V/ 380 V -230 V / 400 V -240 V/ 425 V220 V/ 380 V -230 V / 400 V -240 V/ 425 V220 V/ 380 V -230 V / 400 V -240 V/ 425 V
AC voltage range160 V TO 300 V160 V TO 300 V160 V TO 300 V
AC Grid frequency 16.8 A16 A19.1 A
Rated grid frequency / rated grid voltage 50 HZ/ 230 V
Max Output Current 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited
Power factor at rated active power111
Adjustable Displacement 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited
feed-in phase 333
Harmonic Distortion (THD) at rated out put <3%<3%<3%
Efficiency and Protection
Max efficiency / European efficiency98.6 % / 98.2 %98.6 % / 98.2 %98.6 % / 98.2 %
DC Isolator
Ground fault monitoring
grid monitoring
CS reverse polarity protection/ AC Short circuit current capability.
ALL-pole- sensitive residual- current monitoring unit 17. 3 KG17. 3 KG17. 3 KG
Protection class( according ti IEC 62109-1)/ overvoltage category( according to IEC 62109-1)I/AC: III; DC: III/AC: III; DC: III/AC: III; DC: II
General Data
Dimension ( w/h/ d)
Weight 17.3 KG 17. 3 KG 17.3 KG
Operating temperature range-25 C -+60 C -25 C -+60 C -25 C -+60 C
Self Consumption (at night) <1W<1W<1W
Topology TransformerlessTransformerlessTransformerless
Cooling Concept Active cooling Active cooling Active cooling
Degree of protection ( according to IEC 60529IP65IP65IP65
Climatic category ( according to IEC 60721- 3-44K4H4K4H4K4H
Max permissible valuable for relative Humidity ( non- condensing)100%100%100%
Max operating altitude 3000 M3000 M3000 M
Features:
DC connectionPhoenix contact Phoenix contact Phoenix contact
AC connection plug- in connector plug- in connector plug- in connector
MOUNTING TYPEwall- mount bracketwall- mount bracketwall- mount bracket
LED indicator ( status/ Fault/ Communication
Communication interface wi-Fi/ Rs485wi-Fi/ Rs485wi-Fi/ Rs485
Certificate ad approvals ( more available on request)

CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11