KNOX ASW13K-LT-G2 (13 KW)

Description

Technical Data Sheet 12K-LT- G2 13K-LT- G215K-LT-G2
Input DC
Max PV array Power1100 v 1100 v 1100 v
Max input voltage18000 WP STC19500 WP STC225000 WP STC
MPP Voltage range/ rated input voltage150 v to 1000 v / 630 v150 v to 1000 v / 630 v150 v to 1000 v / 630 v
Main Input voltage 125 v 125 v 125 v
Initial Feed- in voltage 150 v26 A /26 A 150 v 150 v 26 A /26 A
Max Operating input current
26 A /26 A40 A / 20 A40 A / 20 A
Max short circuit current40 A / 20 A2/A:2; B:12/A:2; B:1
Number of independent MPP inputs/ String per MPP input2/A:2; B:1
12000 W
13000 W15 000 W
OUTPUT AC:13000 VA15000 VA
Rated active power12000 VA
13000 VA 15000 VA
Max apparent AC Power12000 VA
160V TO 300 V160V TO 300 V
AC nominal voltage 22O V / 380V- 230V/ 400V- 240 V /415 V 22O V / 380V- 230V/ 400V- 240 V /415 V 22O V / 380V- 230V/ 400V- 240 V /415 V
AC voltage range160 V TO 300 V160 V TO 300 V160 V TO 300 V
AC Grid frequency 50 HZ /45 HZ TO 55 HZ - 60 HZ 55HZ- TO 65 HZ 50 HZ /45 HZ TO 55 HZ - 60 HZ 55HZ- TO 65 HZ 50 HZ /45 HZ TO 55 HZ - 60 HZ 55HZ- TO 65 HZ
Rated grid frequency / rated grid voltage 50 HZ / 230 V50 HZ / 230 V50 HZ / 230 V
Max Output Current 19.1 A20.7 A24 A
Power factor at rated active power111
Adjustable Displacement 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited 0.8 overexcited to 0.8 underexcited
feed-in phase333
Harmonic Distortion (THD) at rated out put <3%<3%<3%
Efficiency and Protection
Max efficiency / European efficiency98.6 % / 98.2 %98.6 % / 98.2 %98.6 % / 98.2 %
DC Isolator
Ground fault monitoring
grid monitoring
CS reverse polarity protection/ AC Short circuit current capability.
ALL-pole- sensitive residual- current monitoring unit
Protection class( according ti IEC 62109-1)/ overvoltage category( according to IEC 62109-1)I/AC: III; DC: III/AC: III; DC: III/AC: III; DC: II
General Data
Dimension ( w/h/ d)
503/ 435/ 183 MM503/ 435/ 183 MM503/ 435/ 183 MM
Weight 17.3 KG 17.3 KG 17.3 KG
Operating temperature range-25 C -+60 C -25 C -+60 C -25 C -+60 C
Self Consumption (at night) <1W<1W<1W
Topology TransformerlessTransformerlessTransformerless
Cooling Concept Active cooling Active cooling Active cooling
Degree of protection ( according to IEC 60529IP65IP65IP65
Climatic category ( according to IEC 60721- 3-44K4H4K4H4K4H

Max permissible valuable for relative Humidity ( non- condensing)
Max operating altitude 3000 M3000 M3000 M
Features:
DC connectionPhoenix contact Phoenix contact Phoenix contact
AC connection Plug- in connector Plug- in connector Plug- in connector
MOUNTING TYPEwall- mount bracketwall- mount bracketwall- mount bracket
LED indicator ( status/ Fault/ Communication
Communication interface wi-Fi/ Rs485wi-Fi/ Rs485wi-Fi/ Rs485
Certificate ad approvals ( more available on request)

CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11