Sale!

JFY ON-GRID SOLAR INVERTER 10000TL+ (10KW)

155000

Description

Product Characteristics     
Model No.5000TL+ (5KW)8000TL+ (8KW)10000TL+ (10KW)12000TL+ (12KW)15000TL+ (15KW)
Warranty
Product Warranty (Min)5 Years5 Years5 Years5 Years5 Years
Input Data(DC)
Max. DC Power5.15 kW8.2 kW11.2 kW13.3 kW16.5 kW
Max. DC Voltage900 V1000 V1000 V1000 V1000 V
Min. DC Voltage to Start Feed In250 V250 V250 V250 V250 V
Max. DC Current20 A32 A44 A48 A60 A
MPP(T) Voltage Range250~720 V250~720 V250~800 V250~800 V250~800 V
No of MPP Trackers22222
DC Inputs22244
Output Data (AC)
Max. AC Power5 kW8 kW10 kW12 kW15 kW
Nominal AC Power5 kW8 kW10 kW12 kW15 kW
Output AC Voltage Range360~440 V360~440 V360~440 V360~440 V360~440 V
Nominal AC Voltage400 V400 V400 V400 V400 V
Max. AC Current7.9 A12.7 A16 A19.4 A25 A
Nominal AC Current7.3 A11.6 A15.2 A17.4 A22.7 A
Frequency Range45-65 Hz45-65 Hz45-65 Hz45-65 Hz45-65 Hz
Frequency50, 60 Hz50, 60 Hz50, 60 Hz50, 60 Hz50, 60 Hz
Power Factor (cosθ)0.90.90.90.90.9
Distortion (THD)< 3 %< 3 %< 3 %< 3 %< 3 %
No of feed-in phases33333
Max. Efficiency97.7 %98 %98.1 %98.1 %98.1 %
Euro Efficiency96.8 %97.3 %97.5 %97.5 %97.6 %
General Data
Dimensions (H/W/D)560x470x165 mm585x470x165 mm585x470x165 mm670x470x165 mm670x470x165 mm
Weight32 kg32 kg35 kg35 kg50 kg
Power Consumption at Night!ERROR! undefined variable 'w'!ERROR! undefined variable 'w'!ERROR! undefined variable 'w'!ERROR! undefined variable 'w'!ERROR! undefined variable 'w'
Noise Level< 25 dB(A) < 25 dB(A)< 25 dB(A)< 25 dB(A)< 25 dB(A)
Operating Temperature-25 ~ +60 ℃-25 ~ +60 ℃-25 ~ +60 ℃-25 ~ +60 ℃-25 ~ +60 ℃
TransformerTransformer lessTransformer lessTransformer lessTransformer lessTransformer less
Protection ClassIP65IP65IP65IP65IP65
CoolingNaturalNaturalNaturalNaturalNatural
interfaceRS 232, RS 485, WLANRS 232, RS 485, WLANRS 232, RS 485, WLANRS 232, RS 485, WLANRS 232, RS 485, WLAN
DisplayLCDLCDLCDLCDLCD
Protection Features
Protection FeaturesAnti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid MonitoringAnti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid MonitoringAnti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid MonitoringAnti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid MonitoringAnti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid Monitoring